(This functionality is available with the Survey Live module)
Used to perform a field setout. The
Setout activity is accessed from the Survey Live main dialog.
Note that different commands are available depending on whether Survey Live was last configured for Total Station or GNSS instrument type.
Survey Live/Setout activity
Total Station
Item | Used to |
Meas | Measure and automatically store a point. |
Dist | Measure a distance and display the results on the observation page.
Note: The point will not be stored until the Store button has been pressed. |
Store | Store the currently measured point. Note: This button will not be active until the Dist button has been pressed. |
GNSS
Item | Used to |
Measure | Start measuring the current point. Only available when using the Coding, Observation and Offsets pages. |
Stop | Stop measuring. Only available when using the Coding, Observation, Offsets and Auto pages and only after Measure or Start has been activated. |
Store | Store the result of a measurement. Only available when using the Coding, Observation and Offsets pages and only after Stop has been selected. |
Start | Start auto measuring. Only available when using the Auto Page. Measurements will be automatically stored according the Auto Points settings in the Configure/Survey page. |
Common
Item | Used to |
Config | Display the Configuration pages. |
More | Display more of Survey Live dialog. |
Less | Display less of Survey Live dialog. |
Back | Return to the Main command buttons. |