Input IntersectionInput Intersection

(This functionality is available with the Input / Output module)

Allows manual input of direction observations to obtain a least squares intersection solution. The observations are stored in a Field File.

The Input/Intersection command is selected from the Field Transfer task.

You may use the Field file dialog box to select the data path and the name of the field file to be used for storing the observations entered.

Select the required data path by double clicking the required folder in the folders list box. Then click in the file field and key in a new field file name, or select an existing field file from the field file list box. Click the OK button to open the field file. If the selected file already exists, you may append to it or overwrite it by clicking the appropriate button when warned of the file's existence.

After selecting the field file, use the Intersection dialog box for entering the observations.

In the New Point Sighted group box, click in the Point Identifier field and key in the identifier of the new point to which the directions were observed and for which the intersected co-ordinates are required. You may also enter a Code and description for this point.

After entering the New Point Identifier, click the OK button to transfer focus to the Sighted From group box.

With the focus in the Sighted From group box, click in the Point Identifier field and key in the identifier of the first point observed from. Use the TAB key or the mouse to move to the other data fields and key in the observed values for Bearing In and SD (Standard Deviation). Press the ENTER key or click the OK button to record the observation in the field file. The focus will then go to the Point Identifier field for entry of the next observation. After entering all observations click the Exit button to close the dialog box.