(This functionality is available with the Input / Output module)
This topic documents the field operations for a TC-600 with firmware version 2.x. If your TC-600 has firmware version 1.x, refer to the TC-600 V1 topic.
For the TC-600 Version 2.x firmware, use the normal LEICA/WILD Operation Codes with the following differences.
OPERATION CODE 1 - New Set Up
1. Station Point Identifier
2. Backsight Station Point Identifier - Optional
(Height of instrument is set by the measurement word index 88)
(Height of target is set by the measurement word index 87)
OPERATION CODE 2 - New Target Height
This operation code is not supported
Height of target is set by the measurement word index 87
OPERATION CODE 7 - Circle with Radii (After Observation)
1. Radius
2. Radius } Optional
3. Radius } Optional
A maximum of 3 circles can be defined.
OPERATION CODE 9 - Fixed Co-ordinate
This operation code is not supported
Co-ordinates can be entered by the measurement word indices 81, 82 and 83.
OPERATION CODE 14 - Description (After Observation)
1. Description
2. Description (Optional)
3. Description (Optional)
Descriptions may be a maximum of 24 characters.
OPERATION CODE 16 - Point on Line
This operation code is not supported
OPERATION CODE 21 - Personnel
1. Surveyor
2. Party (Optional)
3. Party (Optional)
The Personnel description may be a maximum of 24 characters.
OPERATION CODES 40 to 48 -Define Field Templates (before observations)
Retrieve Field Templates (after first observation in template)
1. First Feature Code
2. Second Feature Code
3. Third Feature Code
A maximum of 3 codes per field template line can be entered.
The Operation Code may be repeated another 4 times to define up to 12 feature codes in a field template.
Up to 9 field templates, each using one of the operation codes 40 to 48, and each containing as many as 12 feature codes, may be defined and retrieved during a field session.
OPERATION CODES 50 to 59 -Predefined codes
1. Operation code
2. First Information Word of Operation Code
3. Second Information Word of Operation Code
Codes 50 to 59 can be used to pre-define commonly used operation codes.
The operation codes that can be pre-defined are restricted to those with a maximum of 2 information words.