(This functionality is available with the Input / Output module)
This topic documents the process for transferring data between the TC-600 and the system. Please refer also to the TC-600 Field Operations topic for information about the field procedures and coding methods.
Transferring data from the TC-600
Ensure that you have carried out the appropriate steps in the procedure for Processing a Field Survey up to the step for initiating the transfer of the data. Then, to initiate the transfer, carry out the following on the TC-600.
Item | Used to |
Menu: | Display the TC-600 menu |
All: | Arrow down to Conf. |
Cont: | Display the Configure Menu |
All: | Arrow down to Interface |
Cont: | Display Interface parameters |
All: | Arrow back to Endmark |
Rec: | Toggle Endmark from CR to CR/LF |
Cont: | Display Interface Menu |
Stop: | Display TC-600 Menu |
Dist: | Arrow up to Prog |
Cont: | Display Prog menu |
All: | Arrow down to Filetrans |
Cont: | Display download options |
Cont: | Download data |
Stop: | Return to measurement display when download complete. |
Transferring co-ordinate data to the TC-600
Use the Output/Data Recorder command to put the system in a ready state to send co-ordinates to the TC-600. A dialog box should be displayed asking if the data recorder is ready to receive data. Then, to place the TC-600 in a ready state, carry out the following on the TC-600.
Item | Used to |
Menu: | Display the TC-600 menu |
All: | Arrow down to Prog. |
Cont: | Display the Prog Menu |
All: | Arrow down to Filetrans |
Cont: | Display Filetrans menu |
All: | Arrow down to Load |
Cont: | Display Load Options |
Cont: | Append to existing file if one existing |
Now select the OK button in the system dialog box to commence the data transfer. | |
Stop: | Return to measurement display when upload complete. |